Product Code: 4719003621254
Manufacturer: AGS
14 points to the loyalty system
Fast shipping
95% of all orders are dispatched within 24 hours.
Certified children’s products
Certified in accordance with applicable EU standards.
Tested by tens of thousands of families
Tens of thousands of families in the EU use our products every day.
Design without compromise
Thought through down to the last detail.
Medically highly effective compressor inhaler for children in an attractive design for fast, comfortable and pleasant treatment for the whole family.
Inhaler for effective treatment of upper and lower respiratory tract. The high-speed atomizer provides short inhalation times. Child-friendly design to make treatment more pleasant. The device is suitable for all common inhalation solutions and is easy to operate with one button. Accessories can be washed and disinfected.
The grip for the spray bottle allows it to be conveniently placed at the back of the device in the shape of a teddy bear. The device with the spray can will thus be ready for further use.
Technical parameters:
- Aerosol output: 0.4 ml/min. (NaCI 0.9%)
- Particle size: 71.2% <5 μm, 3.16 μm (MMAD)
- Max. free air flow: 15 l/min.
- Operating air flow: 5.31 l/min.
- Noise level: 52 dBA
- Supply cord length: 1.6 m
- Spray cup capacity: min. 2 ml; max. 8 ml
- Residual volume: 0.8 ml
- Operating restrictions: 30 min. ON / 30 min. OFF
- Operating conditions: 10-40 °C
- Weight: 1500 g
- Dimensions: 120 x 180 x 140 mm
- Estimated lifetime: 1 000 hours
- Warranty period: 5 years
Important safety instructions
- Follow the instructions for use. This manual contains important information about the operation and safety of this device. Read this manual thoroughly before using the device and keep it for future reference.
- This instrument may only be used for the purposes described in this manual. The manufacturer is not liable for damages caused by improper use.
- Read the instructions carefully before using the device and keep them for future reference.
- Do not operate the device in the presence of any flammable mixture of anaesthetics together with oxygen or nitrogen compounds.
- This device is not suitable for anaesthesia and pulmonary ventilation.
- It should only be used with original accessories as specified in this manual.
- Do not use the device if you think it is damaged or if you notice anything unusual about it.
- Never disassemble the device.
- This instrument contains sensitive components and must be handled with care. Observe the conditions for
storage and operation as described in the "Technical Specifications" section!
- Protect the device from:
- water and humidity
- extreme temperatures
- bumping and dropping to the ground
- pollution and dust
- direct sunlight
- heat and cold
- Observe the safety principles when using electrical equipment, in particular:
- Never touch the device with wet or damp hands.
- Place the unit on a stable and level surface during operation.
- Do not pull on the cord or the whole device to disconnect it from the mains socket.
- The power plug is a separate power supply element, separable from the mains; keep the plug accessible when the equipment is in use.
- Before connecting the appliance to the mains, make sure that the information on the type plate
of the instrument, located on the bottom of the instrument, are the same as the mains values.
- In the event that the power cord supplied with the unit does not fit into your outlet, contact qualified personnel for a replacement extension. In general, the use of adapters, single or multiple and/or extension cords is not recommended. If they are used, it is necessary to use types complying with safety regulations. Make sure that the maximum power supply values indicated on the adapters and extension cables are not exceeded.
- Do not leave the unit plugged into the mains when the unit is not in use; unplug the unit from the mains socket when not in use.
- Installation must be carried out in accordance with the manufacturer's instructions. Improper installation may cause damage to persons, animals or objects for which the manufacturer cannot be held responsible.
- Do not replace the power cord of this device. If the power cord is damaged, contact a manufacturer-approved service center for replacement.
- The power cord must always be stretched to avoid the risk of overheating.
- Before starting any maintenance or cleaning, turn off the unit and disconnect the power cord from the mains.
- For inhalation, use only the medication prescribed by your doctor and follow your doctor's instructions regarding dosage, duration and frequency of treatment.
- Use only the medication recommended by your doctor to treat your condition.
- Only use the nasal attachment if specifically advised to do so by your doctor, taking special care to NEVER push the bifurcation holes of the nasal attachment into the nose, but only place them as close to the nostrils as possible.
- Read the package insert of the selected drug for possible contraindications when used with conventional aerosol therapy.
- Position the device so that it can be easily disconnected.
- For greater hygienic safety, do not use the same accessory for more than one person.
- Never bend the sprayer more than 60°.
- Do not use the device near strong electromagnetic fields, e.g. mobile phones or radio equipment. Use the device at a distance of at least 3.3 m from sources of magnetic radiation.
Make sure that the device is not used by unsupervised children; some parts are so small that they can be swallowed. If the device is supplied with a cable or hose, there is a risk of strangulation.
The use of this device should not be considered as a substitute for a consultation with your physician.
This device is not a toy! Keep out of reach of children and do not leave children during treatment.
Manufacturer's address:
Microlife AG Swiss Corporation
Espenstrasse 139
CH-9443 Widnau/ Switzerland
Exclusive importer to the Slovak Republic:
INTERPHARM Slovakia, as
Uzbek 18/A
821 06 Bratislava
Slovak Republic
Tel: +421 2 402 00 430-4, 402 00 400
www.microlife.sk
Inhaler for effective treatment of upper and lower respiratory tract. The high-speed atomizer provides short inhalation times. Child-friendly design to make treatment more pleasant. The device is suitable for all common inhalation solutions and is easy to operate with one button. Accessories can be washed and disinfected.
The grip for the spray bottle allows it to be conveniently placed at the back of the device in the shape of a teddy bear. The device with the spray can will thus be ready for further use.
Technical parameters:
- Aerosol output: 0.4 ml/min. (NaCI 0.9%)
- Particle size: 71.2% <5 μm, 3.16 μm (MMAD)
- Max. free air flow: 15 l/min.
- Operating air flow: 5.31 l/min.
- Noise level: 52 dBA
- Supply cord length: 1.6 m
- Spray cup capacity: min. 2 ml; max. 8 ml
- Residual volume: 0.8 ml
- Operating restrictions: 30 min. ON / 30 min. OFF
- Operating conditions: 10-40 °C
- Weight: 1500 g
- Dimensions: 120 x 180 x 140 mm
- Estimated lifetime: 1 000 hours
- Warranty period: 5 years
Important safety instructions
- Follow the instructions for use. This manual contains important information about the operation and safety of this device. Read this manual thoroughly before using the device and keep it for future reference.
- This instrument may only be used for the purposes described in this manual. The manufacturer is not liable for damages caused by improper use.
- Read the instructions carefully before using the device and keep them for future reference.
- Do not operate the device in the presence of any flammable mixture of anaesthetics together with oxygen or nitrogen compounds.
- This device is not suitable for anaesthesia and pulmonary ventilation.
- It should only be used with original accessories as specified in this manual.
- Do not use the device if you think it is damaged or if you notice anything unusual about it.
- Never disassemble the device.
- This instrument contains sensitive components and must be handled with care. Observe the conditions for
storage and operation as described in the "Technical Specifications" section!
- Protect the device from:
- water and humidity
- extreme temperatures
- bumping and dropping to the ground
- pollution and dust
- direct sunlight
- heat and cold
- Observe the safety principles when using electrical equipment, in particular:
- Never touch the device with wet or damp hands.
- Place the unit on a stable and level surface during operation.
- Do not pull on the cord or the whole device to disconnect it from the mains socket.
- The power plug is a separate power supply element, separable from the mains; keep the plug accessible when the equipment is in use.
- Before connecting the appliance to the mains, make sure that the information on the type plate
of the instrument, located on the bottom of the instrument, are the same as the mains values.
- In the event that the power cord supplied with the unit does not fit into your outlet, contact qualified personnel for a replacement extension. In general, the use of adapters, single or multiple and/or extension cords is not recommended. If they are used, it is necessary to use types complying with safety regulations. Make sure that the maximum power supply values indicated on the adapters and extension cables are not exceeded.
- Do not leave the unit plugged into the mains when the unit is not in use; unplug the unit from the mains socket when not in use.
- Installation must be carried out in accordance with the manufacturer's instructions. Improper installation may cause damage to persons, animals or objects for which the manufacturer cannot be held responsible.
- Do not replace the power cord of this device. If the power cord is damaged, contact a manufacturer-approved service center for replacement.
- The power cord must always be stretched to avoid the risk of overheating.
- Before starting any maintenance or cleaning, turn off the unit and disconnect the power cord from the mains.
- For inhalation, use only the medication prescribed by your doctor and follow your doctor's instructions regarding dosage, duration and frequency of treatment.
- Use only the medication recommended by your doctor to treat your condition.
- Only use the nasal attachment if specifically advised to do so by your doctor, taking special care to NEVER push the bifurcation holes of the nasal attachment into the nose, but only place them as close to the nostrils as possible.
- Read the package insert of the selected drug for possible contraindications when used with conventional aerosol therapy.
- Position the device so that it can be easily disconnected.
- For greater hygienic safety, do not use the same accessory for more than one person.
- Never bend the sprayer more than 60°.
- Do not use the device near strong electromagnetic fields, e.g. mobile phones or radio equipment. Use the device at a distance of at least 3.3 m from sources of magnetic radiation.
Make sure that the device is not used by unsupervised children; some parts are so small that they can be swallowed. If the device is supplied with a cable or hose, there is a risk of strangulation.
The use of this device should not be considered as a substitute for a consultation with your physician.
This device is not a toy! Keep out of reach of children and do not leave children during treatment.
Manufacturer's address:
Microlife AG Swiss Corporation
Espenstrasse 139
CH-9443 Widnau/ Switzerland
Exclusive importer to the Slovak Republic:
INTERPHARM Slovakia, as
Uzbek 18/A
821 06 Bratislava
Slovak Republic
Tel: +421 2 402 00 430-4, 402 00 400
www.microlife.sk
Parameters
| Nomenclature | 90192090 |
|---|