MICROLIFE Compressor inhaler 2 in 1 NEB Pro

Product Code: F131668
Manufacturer: AGS
20 points to the loyalty system
AGS

Product Code: F131668Shipping and Payment

83 EUR incl. VAT

Currently unavailable Watch availability
65+ zákazníků již nakoupilo tento produkt
Do you need advice?

Fast shipping

95% of all orders are dispatched within 24 hours.

Certified children’s products

Certified in accordance with applicable EU standards.

Tested by tens of thousands of families

Tens of thousands of families in the EU use our products every day.

Design without compromise

Thought through down to the last detail.

The Professional Compressor Inhaler is a complete aerosol therapy system for everyday home use to treat the upper and lower respiratory tract. It is equipped with a powerful and quiet compressor suitable for continuous operation. Complete accessories allow therapy of the upper, middle and lower airways.

The nasal douche is intended for regular rinsing of the nose as a prevention of diseases in the nose and sinuses. It removes dust and pollen from the nose and alleviates difficulties in allergic reactions, increases the resistance of the nasal mucous membranes against bacterial and viral infections. The shower is also very helpful for common colds and similar problems related to the nasal cavity. It helps with dry nose, asthma and bronchitis by loosening mucus and then clearing the airways.

NEB PRO is intended for preventive and therapeutic use:

- nasal douche to rinse the nasal mucosa and upper respiratory tract

- fast and effective treatment of allergic and non-allergic rhinitis, sinusitis, nasal polyps

- inhaler for the treatment of middle and lower respiratory conditions such as asthma, chronic bronchitis and cystic fibrosis

Technical parameters:

- aerosol output: 0.37 ml/min. (0.9% NaCI)

- particle size: 57% < 5 μm; 3.5 μm (MMAD)

- max. free air flow: 15 l/min.

- operating air flow: 5.31 l/min.

- noise level: 52 dBA

- power supply: 230V, 50 Hz

- power cable length: 1.6 m

- spray container capacity: min. 2 ml; max. 8 ml

- residual volume: 0.8 ml

- operational restrictions: permanent use

- operating conditions: 10 - 40 °C

- weight: 1765 g

- dimensions: 289 x 180 x 127 mm

- IP class: IP21

- related standards: EN 13544-1; EN 60601-1; EN 60601-2; EN 60601-1-6; IEC 60601-1-11

- life expectancy: 1000 hours of operation

- the device complies with the requirements of Directive 93/42/EEC on medical devices

5 years warranty on the device.

Important safety instructions
- Follow the instructions for use. This manual contains important information on operation and safety
of this device. Read this manual thoroughly before using the instrument and keep it for future reference.
- This instrument may only be used for the purposes described in this manual. The manufacturer is not liable for damages caused by improper use.
- Do not operate the device in the presence of any flammable mixture of anaesthetics together with oxygen or nitrogen compounds.
- This device is not suitable for anaesthesia and pulmonary ventilation.
- The device should only be used with original accessories as specified in this manual.
- Do not use the device if you think it is damaged or if you notice anything unusual about it.
- Never disassemble the device.
- This instrument contains sensitive components and must be handled with care. Observe the storage and operating conditions described in the section "Technical Specifications"!
- Protect the device from:
- water and humidity,
- extreme temperatures,
- bumping and dropping to the ground,
- pollution and dust,
- direct sunlight,
- heat and cold.
- Observe the safety principles when using electrical equipment, in particular:
- never touch the device with wet or damp hands,
- place the device on a stable and horizontal surface during operation,
- do not pull on the cord or the whole device to disconnect it from the mains socket,
- the power plug is a separate power supply element, separable from the mains; keep the plug accessible when the equipment is in use.
- Before connecting the instrument to the mains, make sure that the information on the type plate on the bottom of the instrument matches the mains values.
- In the event that the power cord supplied with the unit does not fit into your outlet, contact qualified personnel for a replacement extension. In general, the use of adapters, single or multiple and/or extension cords is not recommended. If they are used, it is necessary to use types complying with safety regulations. Make sure that the maximum power supply values indicated on the adapters and extension cables are not exceeded.
- Do not leave the unit plugged into the mains when the unit is not in use; unplug the unit from the mains socket when not in use.
- Installation must be carried out in accordance with the manufacturer's instructions. Improper installation may cause damage to persons, animals or objects for which the manufacturer cannot be held responsible.
- Do not replace the power cord of this device. If the power cord is damaged, contact a manufacturer-approved service center for replacement.
- The power cord must always be stretched to avoid the risk of overheating.
- Before starting any maintenance or cleaning, turn off the unit and disconnect the power cord from the mains.
- For inhalation, use only the medication prescribed by your doctor and follow your doctor's instructions regarding dosage, duration and frequency of treatment.
- Do not use the following medications: do NOT use hyaluron.
- Use only the medication recommended by your doctor to treat your condition.
- Only use the nasal attachment if specifically advised to do so by your doctor, taking special care to NEVER push the bifurcation holes of the nasal attachment into the nose, but only place them as close to the nostrils as possible.
- Read the package insert of the selected drug for possible contraindications when used with conventional aerosol therapy.
- Position the device so that it can be easily disconnected.
- For greater hygienic safety, do not use the same accessory for more than one person.
- Never bend the sprayer more than 60°.
- Do not use the device near strong electromagnetic fields, e.g. mobile phones or radio equipment. Use the device at a distance of at least 3.3 m from sources of magnetic radiation.
Make sure that the device is not used by unsupervised children; some parts are so small that they can be swallowed. If the device is supplied with a cable or hose, there is a risk of strangulation.
The use of this device should not be considered as a substitute for a consultation with your physician.

Manufacturer's address:
Microlife AG Swiss Corporation
Espenstrasse 139
CH-9443 Widnau/ Switzerland

Exclusive importer to the Slovak Republic:
INTERPHARM Slovakia, as
Uzbek 18/A
821 06 Bratislava
Slovak Republic
Tel: +421 2 402 00 430-4, 402 00 400
www.microlife.sk
Parameters
Nomenclature 90192090