MICROLIFE Breast milk pump duo electric 2in1, BC 300 Maxi
Product Code: F131673
Manufacturer: AGS
35 points to the loyalty system
Fast shipping
95% of all orders are dispatched within 24 hours.
Certified children’s products
Certified in accordance with applicable EU standards.
Tested by tens of thousands of families
Tens of thousands of families in the EU use our products every day.
Design without compromise
Thought through down to the last detail.
The pump's innovative dual-use technology is suitable for pumping milk from one or both breasts simultaneously. It is gentle, practical and time-saving to use. The dual suction system allows you to pump more milk in less time. Use is very convenient thanks to the function of saving settings in the memory of the device. The bottle does not contain BPA at all.
The Dual Electric Breast Pump is an amazing time saver for mothers. Dual vacuum technology allows you to express more milk in less time than conventional single breast pumps. Pumping simultaneously from both breasts is more efficient and also promotes higher breast milk production.
Features:
- time-saving dual extraction technology
- highest comfort with 10 different levels of stimulation before suction and 10 levels of suction intensity
- large illuminated display timer measures stimulation and milk expressing time
- operation on mains and battery power (low battery indicator)
- 180 ml milk bottle with silicone teat, cap and bottle holder included
- silicone soother with double anti-colic valve ensures maximum protection against colic - the soother is always full of milk to prevent swallowing air when feeding the baby
- adapter for NUK and AVENT bottles
- hygienic bag for storage and carrying
Technical documentation:
- type: dual electric breast pump BC 300 Maxi 2 in 1
- frequency of use: regular use
- stimulation levels: 10
- suction levels: 10
- dimensions of the device: 130 x 120 x 57 mm
- weight: 330 g (without battery)
- maximum suction pressure: -0.32 bar
- operating conditions: 5-40°C, ambient pressure 700-1060 hPa
- power supply: 4 x 1.5 V alkaline AA batteries
- power adapter: input: 100-240 V, 50/60 Hz, 0.5 A, output: = 6 V, 1 A
- battery life: 500 hours
- expected lifetime: 500 hours
- operating restrictions: 30 min. ON / 30 min. OFF
Warranty 2 years.
Please read the instructions carefully before using this product.
Batteries and electronic devices must be disposed of in accordance with local applicable regulations, not with household waste.
Important safety instructions
Safety and protection
- Follow the instructions for use. This manual contains important information about the operation and safety of this device. Read this manual thoroughly before using the instrument and keep it for future reference.
- This instrument may only be used for the purposes described in this manual. The manufacturer is not liable for damages caused by improper use.
- Keep packaging material out of the reach of children to avoid choking hazards.
- Keep small parts out of the reach of children.
- Make sure that the cables are not accessible to children.
- Use only the mains plug supplied.
- Children must not play with the device.
- Cleaning and maintenance must not be carried out by children unless supervised.
- The device should only be used with original accessories as specified in this manual.
- For hygiene reasons, only one person may use the device. Do not share the device with other nursing mothers.
- The device may only be used on female breasts.
- Never use the device if you feel sleepy or if you are asleep.
- Never use the device in the bath or shower.
- Do not use the device if you think it is damaged or if you notice anything unusual about it.
- Never disassemble the device.
- This device must not be used by persons with reduced physical, sensory or mental abilities or with lack of experience or knowledge.
- Repairs may only be carried out by customer service or an authorised dealer. Under no circumstances should you open or repair the device yourself, as trouble-free operation can no longer be guaranteed. Failure to comply with these conditions will result in the termination of the warranty.
- Never immerse the device in water.
- Never touch the device if it has fallen into water. If the device has fallen into water, immediately pull the mains plug out of the socket.
- Unwind the power cord completely to prevent overheating.
- Never place the appliance or the mains plug in the microwave oven.
- Never heat breast milk in the microwave, as it may heat unevenly and could burn your baby when she drinks it.
- When you are not using the device, unplug the mains plug from the socket. Do not leave the device plugged into a socket.
- If the power cable of the device is damaged, the cable must be disposed of.
- Keep the power cord well away from hot surfaces.
- The device does not require calibration.
- No modifications to the equipment are allowed.
IMPORTANT
- Never wet the device with water. It is not protected against splashing water or liquids.
- Do not use the device near strong electromagnetic fields, e.g. mobile phones or radio equipment.
Use the device at a distance of at least 3.3 m from sources of magnetic radiation.
- This instrument contains sensitive components and must be handled with care. Observe the storage and operating conditions described in the section "Technical Specifications"!
- Protect the device from:
- water and humidity,
- extreme temperatures,
- bumping and dropping to the ground,
- pollution and dust,
- direct sunlight,
- heat and cold.
- Observe the safety principles when using electrical equipment, in particular:
- never touch the device with wet or damp hands,
- place the device on a stable and horizontal surface during operation,
- do not pull on the cord or the whole device to disconnect it from the mains socket,
- the power plug is a separate power supply element, separable from the mains; keep the plug accessible when the equipment is in use.
NOTICE
Child safety
- This device must only be used under the supervision of an adult.
- Continued and prolonged teat feeding can lead to tooth decay.
- Use the teat for feeding, not as a pacifier.
- Always check the temperature of the milk before feeding.
- Before each use, check the device and pull the teat in all directions.
- Discard the teat at the first sign of damage or wear.
- Do not expose the teat to direct sunlight or heat sources, and do not leave it in the disinfectant ("sterilising solution") for longer than recommended, as this could damage it.
- Protect the teat from sugary substances as they can cause tooth decay.
- Do not use abrasives or antibacterial cleaners.
- Sterilize all parts that come into contact with breast milk for five minutes in boiling water.
- Clean the device before each use.
- Ensure that the temperature of the liquid in the bottle never exceeds 50 °C.
Make sure that the device is not used by unsupervised children; some parts are so small that they can be swallowed.
If the device is supplied with a cable or hose, there is a risk of strangulation.
IMPORTANT
When transporting breast milk in a bottle (e.g. when travelling), make sure that the bottle cap is always screwed on tightly.
Notes on handling batteries
- If your skin or eyes come into contact with battery fluid, rinse the affected areas with water and seek medical attention.
- Danger of suffocation! Young children can swallow batteries and choke on them. Keep batteries out of reach of small children.
- Observe the plus (+) and minus (-) polarity signs.
- If the battery has leaked, wear protective gloves and clean the battery compartment with a dry cloth.
- Protect the batteries from excessive heat.
- Danger of explosion! Never throw batteries into a fire.
- Do not recharge or short-circuit the batteries.
- Use only the same or equivalent types of batteries.
- Always replace all batteries at the same time.
- Do not use rechargeable batteries.
- Do not disassemble, split or crush the batteries.
Remove the batteries if the device will not be used for a long period of time.
Cleaning and sterilizing the device
NOTICE
Clean and sterilize the parts of the device that come into direct contact with breast milk before first use and afterwards.
Manufacturer's address:
Microlife AG Swiss Corporation
Espenstrasse 139
CH-9443 Widnau/ Switzerland
Exclusive importer to the Slovak Republic:
INTERPHARM Slovakia, as
Uzbek 18/A
821 06 Bratislava
Slovak Republic
Tel: +421 2 402 00 430-4, 402 00 400
www.microlife.sk
The Dual Electric Breast Pump is an amazing time saver for mothers. Dual vacuum technology allows you to express more milk in less time than conventional single breast pumps. Pumping simultaneously from both breasts is more efficient and also promotes higher breast milk production.
Features:
- time-saving dual extraction technology
- highest comfort with 10 different levels of stimulation before suction and 10 levels of suction intensity
- large illuminated display timer measures stimulation and milk expressing time
- operation on mains and battery power (low battery indicator)
- 180 ml milk bottle with silicone teat, cap and bottle holder included
- silicone soother with double anti-colic valve ensures maximum protection against colic - the soother is always full of milk to prevent swallowing air when feeding the baby
- adapter for NUK and AVENT bottles
- hygienic bag for storage and carrying
Technical documentation:
- type: dual electric breast pump BC 300 Maxi 2 in 1
- frequency of use: regular use
- stimulation levels: 10
- suction levels: 10
- dimensions of the device: 130 x 120 x 57 mm
- weight: 330 g (without battery)
- maximum suction pressure: -0.32 bar
- operating conditions: 5-40°C, ambient pressure 700-1060 hPa
- power supply: 4 x 1.5 V alkaline AA batteries
- power adapter: input: 100-240 V, 50/60 Hz, 0.5 A, output: = 6 V, 1 A
- battery life: 500 hours
- expected lifetime: 500 hours
- operating restrictions: 30 min. ON / 30 min. OFF
Warranty 2 years.
Please read the instructions carefully before using this product.
Batteries and electronic devices must be disposed of in accordance with local applicable regulations, not with household waste.
Important safety instructions
Safety and protection
- Follow the instructions for use. This manual contains important information about the operation and safety of this device. Read this manual thoroughly before using the instrument and keep it for future reference.
- This instrument may only be used for the purposes described in this manual. The manufacturer is not liable for damages caused by improper use.
- Keep packaging material out of the reach of children to avoid choking hazards.
- Keep small parts out of the reach of children.
- Make sure that the cables are not accessible to children.
- Use only the mains plug supplied.
- Children must not play with the device.
- Cleaning and maintenance must not be carried out by children unless supervised.
- The device should only be used with original accessories as specified in this manual.
- For hygiene reasons, only one person may use the device. Do not share the device with other nursing mothers.
- The device may only be used on female breasts.
- Never use the device if you feel sleepy or if you are asleep.
- Never use the device in the bath or shower.
- Do not use the device if you think it is damaged or if you notice anything unusual about it.
- Never disassemble the device.
- This device must not be used by persons with reduced physical, sensory or mental abilities or with lack of experience or knowledge.
- Repairs may only be carried out by customer service or an authorised dealer. Under no circumstances should you open or repair the device yourself, as trouble-free operation can no longer be guaranteed. Failure to comply with these conditions will result in the termination of the warranty.
- Never immerse the device in water.
- Never touch the device if it has fallen into water. If the device has fallen into water, immediately pull the mains plug out of the socket.
- Unwind the power cord completely to prevent overheating.
- Never place the appliance or the mains plug in the microwave oven.
- Never heat breast milk in the microwave, as it may heat unevenly and could burn your baby when she drinks it.
- When you are not using the device, unplug the mains plug from the socket. Do not leave the device plugged into a socket.
- If the power cable of the device is damaged, the cable must be disposed of.
- Keep the power cord well away from hot surfaces.
- The device does not require calibration.
- No modifications to the equipment are allowed.
IMPORTANT
- Never wet the device with water. It is not protected against splashing water or liquids.
- Do not use the device near strong electromagnetic fields, e.g. mobile phones or radio equipment.
Use the device at a distance of at least 3.3 m from sources of magnetic radiation.
- This instrument contains sensitive components and must be handled with care. Observe the storage and operating conditions described in the section "Technical Specifications"!
- Protect the device from:
- water and humidity,
- extreme temperatures,
- bumping and dropping to the ground,
- pollution and dust,
- direct sunlight,
- heat and cold.
- Observe the safety principles when using electrical equipment, in particular:
- never touch the device with wet or damp hands,
- place the device on a stable and horizontal surface during operation,
- do not pull on the cord or the whole device to disconnect it from the mains socket,
- the power plug is a separate power supply element, separable from the mains; keep the plug accessible when the equipment is in use.
NOTICE
Child safety
- This device must only be used under the supervision of an adult.
- Continued and prolonged teat feeding can lead to tooth decay.
- Use the teat for feeding, not as a pacifier.
- Always check the temperature of the milk before feeding.
- Before each use, check the device and pull the teat in all directions.
- Discard the teat at the first sign of damage or wear.
- Do not expose the teat to direct sunlight or heat sources, and do not leave it in the disinfectant ("sterilising solution") for longer than recommended, as this could damage it.
- Protect the teat from sugary substances as they can cause tooth decay.
- Do not use abrasives or antibacterial cleaners.
- Sterilize all parts that come into contact with breast milk for five minutes in boiling water.
- Clean the device before each use.
- Ensure that the temperature of the liquid in the bottle never exceeds 50 °C.
Make sure that the device is not used by unsupervised children; some parts are so small that they can be swallowed.
If the device is supplied with a cable or hose, there is a risk of strangulation.
IMPORTANT
When transporting breast milk in a bottle (e.g. when travelling), make sure that the bottle cap is always screwed on tightly.
Notes on handling batteries
- If your skin or eyes come into contact with battery fluid, rinse the affected areas with water and seek medical attention.
- Danger of suffocation! Young children can swallow batteries and choke on them. Keep batteries out of reach of small children.
- Observe the plus (+) and minus (-) polarity signs.
- If the battery has leaked, wear protective gloves and clean the battery compartment with a dry cloth.
- Protect the batteries from excessive heat.
- Danger of explosion! Never throw batteries into a fire.
- Do not recharge or short-circuit the batteries.
- Use only the same or equivalent types of batteries.
- Always replace all batteries at the same time.
- Do not use rechargeable batteries.
- Do not disassemble, split or crush the batteries.
Remove the batteries if the device will not be used for a long period of time.
Cleaning and sterilizing the device
NOTICE
Clean and sterilize the parts of the device that come into direct contact with breast milk before first use and afterwards.
Manufacturer's address:
Microlife AG Swiss Corporation
Espenstrasse 139
CH-9443 Widnau/ Switzerland
Exclusive importer to the Slovak Republic:
INTERPHARM Slovakia, as
Uzbek 18/A
821 06 Bratislava
Slovak Republic
Tel: +421 2 402 00 430-4, 402 00 400
www.microlife.sk
Parameters
| Nomenclature | 84141089 |
|---|